Energy chains and cables in cleanrooms

Suitable for cleanrooms, with ESD suitability, space-saving and low vibration

For more than 15 years, igus has been among the frontrunners for energy supply systems in cleanrooms. igus supplies a wide range of IPA-tested e-chains that enable machine-specific energy supply in cleanrooms and are easy to install. As the quality requirements demanded by customers and by test standards for cleanroom technology are constantly growing, igus is continuously working on improving its products.

Energy chains for cleanroom applications

9,047 energy chain series for cleanroom applications, with ISO Class 1 to 5 certification 2)

e-skin

e-skin  
Suitable for cleanrooms and easy to install

  • Space requirement: from 80 mm
  • Cleanroom ISO class 1
  • Safe, robust and flexible

Energy chain system series T3

Energy chain system series T3  
Highly flexible and with very little vibration

  • Inner height hi: 29 mm
  • Inner width Bi: 30 - 120 mm
  • Bend radii R: 38 mm
  • Pitch: 15 mm

Energy chain system series E3

Energy chain system series E3  
Extremely low noise for extremely small installation spaces

  • Inner height hi: 10 - 22 mm
  • Inner width Bi: 20 - 60 mm
  • Bend radii R: 32 - 75 mm
  • Pitch: 16,7 mm

Energy chain system series E6.1

Energy chain system series E6.1  
Extremely quiet with very little vibration

  • Inner height hi: 29 - 80 mm
  • Inner width Bi: 30 - 140 mm
  • Bend radii R: 55 - 150 mm
  • Pitch: 22 mm

Energy chain system series E6.29

Energy chain system series E6.29  
Extremely low noise

  • Inner height hi: 29 - 80 mm
  • Inner width Bi: 30 - 120 mm
  • Bend radii R: 55 - 150 mm
  • Pitch: 22 mm

All test results

The Fraunhofer IPA Institute has tested various igus energy chain series according to DIN EN ISO 14644-1. It is therefore now possible to make accurate statements about the potential cleanroom uses of almost all the main e-chains from igus.
 

Result according to
DIN EN ISO 14644-1
e-chains® seriesReport No.Speed
[m/s]
ISO Class 1e-skin® 0.SK28.068.02.1IG 1907-11250,5 / 1,0 / 2,0
ISO Class 1e-skin® flat SKF12.3.03.0101IG 1907-11250,5 / 1,0 / 2,0
ISO Class 1e-skin® soft SKS28.068.02.1IG 1907-11250,5 / 1,0 / 2,0
ISO Class 1E61.29.050.075.0IG1303-640-10,5 / 1,0 / 2,0
ISO Class 1E3.15.040.075.0IG0704-4000,5 / 1,0 / 2,0
ISO Class 21500.050.038.0IG1303-640-10,5 / 1,0 / 2,0
ISO Class 2T3.29.050.038.0IG1303-640-10,5 / 1,0 / 2,0
ISO Class 2E14.3.038.0IG0308-2951,0
ISO Class 32500.05.055.0IG0308-2952,0
ISO Class 3E6.29.060.150.0IG0704-4000,5 / 1,0 / 2,0
ISO Class 5E4.32.10.063.0IG1303-640-10,5 / 1,0 / 2,0
 

Cables for cleanroom applications

1,084 of all chainflex catalogue cables with IPA-certification to ISO Class 1 or Class 21) (chainflex cables with tested outer jacket material available from stock)
918 types with cleanroom classification IPA Class 1
166 types with cleanroom classification IPA Class 2

Control cable CFSOFT

Control cable CFSOFT  

  • For heavy duty applications
  • PVC outer jacket
  • Flame-retardant
  • UV-resistant
  • Minimum bend radius: 6.8-8.5 x cable diameter

CFBUS.LB bus cable

CFBUS.LB bus cable  

  • For heavy duty applications
  • TPE outer jacket
  • Halogen-free
  • Oil- and UV-resistant

Control cable CF130.UL

Control cable CF130.UL  

  • For medium duty applications
  • PVC outer jacket
  • Flame-retardant
  • Minimum bend radius: 7.5-10 x cable diameter

Control cable CF9.UL

Control cable CF9.UL  

  • For heaviest duty applications
  • TPE outer jacket
  • Oil-resistant
  • PVC- and halogen-free
  • Flexible at low temperatures
  • Minimum bend radius: 5 x cable diameter

Data cable CF240

Data cable CF240  

  • For medium duty applications
  • PVC outer jacket
  • Oil-resistant
  • Flame-retardant
  • Minimum bend radius: 10-12 x cable diameter

CF34.UL.D motor cable

CF34.UL.D motor cable  

  • For heaviest duty applications
  • TPE outer jacket
  • Oil- and UV-resistant
  • Flame-retardant
  • Minimum bend radius: 7.5 x cable diameter

Clean Air pneumatic hose

Clean Air pneumatic hose  

  • For heaviest duty applications
  • PE hose
  • Oil-resistant and coolant-resistant
  • Highly abrasion-resistant
  • Minimum bend radius: 10 x diameter

All test results

If all cables with the same outer jacket are taken into account, 80% of all chainflex cables of Class 1 or 2 in the catalogue have been certified to DIN EN ISO 14644-1.

Result according to
DIN EN ISO 14644-1
chainflex® cableReport No.Speed
[m/s]
measured in applications involving movement
ISO Class 2CFSOFTIG0704-400in series E6.29.060.100.CR, where v= 0.5/ 1.0 / 2.0 m/s
ISO Class 1CFBUS.LBIG0704-400in series E6.29.060.150.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF130.05.12.ULIG1303-640-1in series E61.29.50.075.0.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF130.15.07.ULIG1303-640-1in series E61.29.50.075.0.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF240.02.24IG1303-640-1in series E61.29.50.075.0.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF34.UL.25.04.DIG0704-400in series E6.29.060.150.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF9.15.07IG0704-400in series E6.29.060.150.CR, where v= 0.5 / 1.0 / 2.0 m/s
ISO Class 1CF Clean AirIG0704-400in series E6.29.060.150.CR, at v= 1.0 m/s
ISO Class 2CF5.10.07IG0704-400in series E6.29.060.150.CR, where v= 0.5 / 1.0 / 2.0 m/s

Fraunhofer IPA tests  

During operation, as few particles as possible should be released into the surrounding area. This is especially applicable to moving machine parts such as energy chains and cables. Keeping the release of particles to a minimum requires a high degree of abrasion resistance, which is also an indicator of a long service life. This is a development goal for all igus® products. igus® tests each of its products in elaborate and meticulous test procedures in its own laboratory. Only what meets the standards of our laboratory is then selected for the Fraunhofer IPA tests.
The evidence is supplied by the Fraunhofer IPA Institute, which awards many igus® products the best possible classification, namely ISO Class 1 

Customers' application examples

Fixload

Suitable for cleanrooms and abrasion-resistant

The energy supply systems of the E6 and E14 series are used for the production of Fixloads. The energy chains are suitable for cleanrooms and are wear-resistant.

Wafer handling

Abrasion-resistant

With the E6, the supply of energy for wafer handling in chip production involving acceleration rates of up to 4 m/s² and speeds of up to 6 meters per second is not a problem.

PCB production

Abrasion-resistant

An abrasion-resistant e-skin from igus is used in facilities for the production of printed circuit boards
and semiconductors. Airborne-dust is no longer a problem with the e-skin.

Tested for cleanrooms

Particle abrasion measurement  

Particle abrasion measurement

As an example, the E14 and how it is tested for use in sensitive environments in cleanroom applications is shown here.
 
Test result: The E14, as well as all the energy chains indicated above, are highly wear-resistant and therefore satisfy the requirements for cleanrooms.

1) Individual series of diverse igus® e-chains® from the E6, E6.1, T3, E3, E2/000, E4.1 and easy chain® families have been given ISO Class 1 to ISO Class 5 certification by the Fraunhofer IPA institute in accordance with DIN EN ISO 14644-1 (Report IG1303-640-1, IG0704-400 and IG308-295). This corresponds to 9,047 articles from the e-chain® product range of the same type of construction/based on the same principle.
2) Individual sizes from the drylin® "T", "N" and "W" product range have been given ISO Class 3 to ISO Class 6 certification by the Fraunhofer IPA Institute in accordance with DIN EN ISO 14644-1 (Report IG308-295).
This corresponds to 197 articles from the drylin® product range of the same type of construction/based on the same principle.