Harnessed cables suitable for Festo
readycable® control cable suitable for Festo KPWR-MC-1-SUB-9HC-xxx, base cable PVC 7.5 x d
- Requirements: For medium duty applications
- Outer jacket:
- PVC Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- CFRIP®
- chainflex® class: 4.4.1.1










readycable® control cable suitable for Festo KPWR-MC-1-SUB-9HC-xxx, base cable PUR 6.8 x d
- Requirements: For heavy duty applications
- Outer jacket: PUR
- Overall shield
- Coolant resistant
- Notch-resistant
- Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- CFRIP®
- chainflex® class: 5.5.3.1














readycable® encoder cable suitable for Festo NEBM-S1G9-E-xxx-LE6, base cable PVC 10 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 4.4.2.1










readycable® encoder cable suitable for Festo NEBM-S1G9-E-xxx-LE6, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Notch-resistant
- Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 4.4.3.1














readycable® encoder cable suitable for Festo NEBM-S1G15-E-xxx-LE6, base cable PVC 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 5.5.2.1










readycable® encoder cable suitable for Festo NEBM-S1G15-E-xxx-LE6, base cable PUR 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 5.5.3.1














readycable® encoder cable suitable for Festo NEBM-S1G15-E-xxx-LE6, base cable TPE 6.8 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 6.6.4.1










readycable® encoder cable suitable for Festo KDI-MC-M8-SUB-9-xxx, base cable PVC 10 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 4.4.2.1










readycable® encoder cable suitable for Festo KDI-MC-M8-SUB-9-xxx, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Notch-resistant
- Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 4.4.3.1














readycable® encoder cable suitable for Festo KES-MC-1-SUB-9-xxx, base cable PVC 10 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 4.4.2.1










readycable® encoder cable suitable for Festo KES-MC-1-SUB-9-xxx, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Notch-resistant
- Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 4.4.3.1














readycable® bus cable suitable for Festo FBA-CO-SUB-9-M12, base cable, PVC 12.5 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- UV-resistant
- chainflex® class: 4.3.2.1









readycable® bus cable suitable for Festo FBA-CO-SUB-9-M12, base cable, PUR 12.5 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Overall shield
- Coolant resistant
- Notch-resistant
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Flame retardant
- PVC-free
- Hydrolysis and microbe-resistant
- UV-resistant
- Halogen-free
- chainflex® class: 4.3.3.1
















readycable® bus cable suitable for Festo FBA-CO-SUB-9-M12, base cable, TPE 6.8 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Flame retardant
- Hydrolysis and microbe-resistant
- UV-resistant
- chainflex® class: 6.6.4.1













readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-S1G9, base cable PVC 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 5.5.2.1










readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-N-S1G15, base cable PVC 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Flame retardant
- Silicone-free
- chainflex® class: 5.5.2.1










readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-N-S1G15, base cable PUR 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 5.5.3.1














readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-S1G9, base cable PUR 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PUR
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 5.5.3.1














readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-N-S1G9, base cable TPE 6.8 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 6.6.4.1










readycable® encoder cable suitable for Festo NEBM-M12G8-E-xxx-N-S1G15, base cable TPE 6.8 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA Hydrolysis and microbe-resistant
- Halogen-free
- Silicone-free
- PVC-free
- UV-resistant
- chainflex® class: 6.6.4.1